Source UK76 UK87 UK91
Cruise USS Gurnard HMS Superb
 
Region Beaufort Sea Fram Strait, North Pole Fram Strait, North Pole
Institution Scott Polar Research Institute, University of Cambridge Scott Polar Research Institute, University of Cambridge Scott Polar Research Institute, University of Cambridge
Investigator Dr. Peter Wafhams Dr. Peter Wafhams Dr. Peter Wafhams
Contact email pw1@cam.ac.uk pw1@cam.ac.uk pw1@cam.ac.uk
Project web site NSIDC Submarine Data NSIDC Submarine Data NSIDC Submarine Data
Documentation NSIDC Documentation NSIDC Documentation NSIDC Documentation
Method Uppward Looking Sonar Uppward Looking Sonar Uppward Looking Sonar
Measurement Draft Draft Draft
Recorder UKDIPS Analog/Hand-digitized Analog/Hand-digitized
 
Point data location NSIDC Documentation NSIDC Documentation NSIDC Documentation
Lat min 70.592 72.831 77.046
Lat max 75.265 89.934 88.522
Lon min -154.242 -190.058 -15.742
Lon max -138.251 177.927 40.138
Start date 7-May-76 8-Jun-87 11-May-91
Start year 1976 1987 1991
Start day 98 128 101
End date 10-May-76 26-Jun-87 26-May-91
End year 1976 1987 1991
End day 101 146 116
Number of point samples 1349919 4852720 4852720
Number of clusters 27 109 40
PDF number of bins 300 300 300
PDF bin width 0.01 0.01 0.01
PDF first center 0 0 0
PDF sample intervals (m) 1.00 1.00 1.00
Mean depth (m)
Min depth (m)
Max depth (m)
Mean Spd (knots) 9.9 10.9 5.6
Min Spd (knots) 6.3 2.4 0.9
Max Spd (knots) 11.7 24.9 16.1
Total sample length (km) 1350 4852 1545
Processing Notes The 1976 SPRI data are from USS Gurnard in the Beaufort Sea with approximate latitude/longitude coordinates supplied. Centroids were not determined. An experimental narrow-beam sonar was used (Wadhams and Horne, 1980). The 1987 SPRI data are from the HMS Superb in the Greenland Sea & Eurasian basin. Data are in two legs (a and b). Segments a03 and b46 have insufficient data for analysis. For segments b45, b55, b58, b60 and b61 the ice regime is not conducive to standard analyses; therefore, these segments were processed with level ice slope of 0.05 and minimum lead width set to zero.